| 1006 DC MilliVolt
Source |
1007 DC Millivolt
Potentiometer & Source |
|
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit and overload protection
- Safety terminals
- Battery level indicator
- Portable with protective boot
|
|
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit and overload protection
- Safety terminals
- Battery level indicator
- Null measuring facility
|
| |
1017 Multifunction
Voltage / Current / Resistance Calibrator |
|
- 0.01uV to 10V
- 0.02% accuracy
- Battery / Mains operation
- 30mA Output Current
- 10 ppm/hr Stability
- Battery level indicator
- Safety terminals
|
|
- DC Volts 10nV to 100V
- DC Current 100nA to 100mA
- Resistance 10mOhms to 10kOhms
- 0.005% (50ppm) accuracy
- 1 ppm setting resolution
- Noise <2ppm (0.1 to 1Hz)
- Stability <5ppm/day, <25ppm/yr
|
| |
1024 DC Current
Calibrator |
|
- 100mA output with overload protection
- 0.02% accuracy
- Wide range of applications
- Safety terminals
- Battery level indicator
- Portable with protective boot
|
|
- Up to 100mA output
- 0.02% accuracy
- 10 ppm/hr stability
- Null facility
- Safety terminals
- Battery level indicator
- Portable - Battery and Mains operation
|
| |
1044 Voltage
and Current Calibrator |
|
- 10mV, 100mV, 1V ranges
- 10mA, 100mA ranges
- 0.1% accuracy
- 0 - 8V available
- Precision 10-turn dial
- Battery level indicator
- Battery Powered 9V PP3
|
|
- Source & Measure Current & Voltage
- 0.05% accuracy
- 3 Voltage Ranges: 0 – 20V
- 3 Current Ranges: 0 – 20mA
- Portable with carry case
|
| |
1050 PT100
Simulator (°F) |
|
- Source & Measure Current & Voltage
- 3 Source ranges 0 - 22mA & 0 - 22V
- 3 Measure ranges 0 - 70mA & 0 - 50V
- Transmitter Simulator/Sink
- Output Steps and Ramps
- Fine adjustment (Inching)
- Accuracy 0.02% of span
|
|
- -100°F to + 1000°F
- ± 0.5°F accuracy
- Based on ITS 90 EN60751
- 23 set points
- Exceeds Class A
- Good temperature stability
- Passive resistance source
|
| |
1090
Temperature and Process Calibrator |
|
- 3 Operating modes
- 100mA Source and Load
- 24V Line mode
- 0.02% Accuracy
- Safety terminals
- Battery level indicator
- Portable with protective boot
|
|
- Measure/Simulate 8 thermocouples
- Measure/Simulate PT100
- Measure/Source (uV/mV/mA)
- Display in °C and °F
- 10 point memory recall
- Inching and Step functions
- Process loops 4-20mA and 0-50mA
|
| |
5069 Insulation
Tester Calibrator |
|
- Insulation resistance - 100KΩ to 10GΩ
- Low Ω verification 1Ω, 10Ω, 100Ω, 1KΩ
- Basic accuracy 1%
- 2.5kV max
- Battery operation
- Continuous connection - no arcing
- Fully shrouded safety connectors
|
|
- Insulation resistance - 100KΩ to 100GΩ
- Basic accuracy 1%
- 10kV max
- Battery operation
- Continuous connection - no arcing
- Fully shrouded safety connectors
|
| |
5080 Portable
Appliance Tester / Insulation Tester Calibrator |
|
- Calibrate Ductor Testers
- Calibrate Micro-Ohm meters
- 0.2, 2, 20, 200, 2000mΩ
- 5 point calibration 0, 25, 50, 75, 100%
- Gold plated terminals
- Low thermal emf connection
- Portable robust carrying case
|
|
- Calibration PATs / VDE 0701 testers
- Battery powered
- Voltage/Current display
- Safety interlock feature
- Measure Earth Bond currents
- Measure Load Test currents
- Impact resistant case
|
| |
7005 Loop Calibrator |
|
- Temp Accuracy 0.05 °C (0.09 °F)
- Temp Resolution 0.01 °C (0.02 °F)
- Resistance Accuracy 0.03Ω
- Resistance Resolution 0.01Ω
- Read & Simulate °C, °F, °K, & Ohms
- Ramp & Step
- PT100 plus 7 other RTD types
|
|
- Loop Source - Current or Voltage
- Loop Measure - Current or Voltage
- Loop Current Sink
- Accuracy 0.01%
- Resolution 1uA or 1mV
- Manual Step, Auto-Step and Ramp
- 20mA drive capability into 1100 ohms
|
| |
7040 Digital
Pressure and Current Calibrator |
|
|
- 4 - 20mA or 0 - 10V loops
- 7 calibration set-points
- TxSim and RxTest (Loop-Mate1)
- RxSim and TxTest (Loop-Mate2)
- Auto-Step output - adjustable rate
- Battery powered PP3
- Internal loop drive supply
|
|
- 0.2, 2, 5, 10, 20 bar options
- Pressure/VAC calibration 0.04% acc.
- Loop current calibration
- 9 engineering units
- Min / Max function
- Leak rate function
- 4.5 digit display
|